  1. Fernco yes or no?? - The Building Code Forum

    Apr 25, 2012 · Ok since I get myself into charged debates here is another. Fernco flexible couplings ICC approved or not? Ferncos' own installation instructions say after installation and …

  2. Fernco for sanitary - The Building Code Forum

    May 15, 2023 · Fernco 1056 series is for connecting " CI, PL, Copper, ST or Lead to CI, PL, Copper, ST or Lead". Chapter 7 Sanitary Drainage: Sanitary Drainage, 2020 FBC - Plumbing, …

  3. cLEANOUTS REQUIRED FOR SIPHONIC ROOF DRAINAGE SYSTEMS?

    Nov 28, 2009 · I found this in the design sandard ASPE 45 for siphonic roof drainage: 1.1.3 Local building and plumbing code requirements for pipe cleanouts and prohibitions for reductions in …

  4. 1.5" Drain Pipe Through 2x8" Joists - The Building Code Forum

    Feb 10, 2023 · Or I guess you could install it like no-hub cast iron and use multiple banded couplings (Fernco Proflex 3003-150 or Mission Rubber K-150 for 1.5" copper DWV to 1.5" …

  5. Would you accept this sill plate anchor? | Page 2 - The Building …

    Jan 13, 2010 · The coupling nuts need to be short enough (or a little concrete might need to chipped away so the coupling nut can go deeper). Like anything, some knucklehead could …

  6. HVAC condensate line - The Building Code Forum

    Oct 18, 2020 · Recently had a new hvac system installed in one of my buildings. 5 T split system, they retained the ductwork, replaced the condensor and fan coil units. Question is about the …

  7. Would you accept this sill plate anchor? - The Building Code Forum

    Oct 20, 2009 · I'd go ahead and add the studs or joists as appropriate, put a coupling nut on the short bolt drop another piece of 2X10 between the studs or joists and run a 1/2" bolt, of the …

  8. Metal Fire Sprinkler Piping - The Building Code Forum

    Oct 19, 2009 · take a continuity meter and drop in on either side of the coupling. you'll get dcontinuity. the rubber seals the rolled edge of the pipe, the fitting will make contact, the pipe …

  9. Permanent temporary buildings without foundation - The Building …

    Oct 17, 2009 · There are exceptions for small buildings of low importance from 2012 IBC1809.5 Frost protection. Except where otherwise protected from frost, foundations and other …

  10. Penetrations followed by flex duct within rated floor-ceiling …

    Oct 19, 2009 · Given:2009 IBCFour story apartments = R2 occupancy.Fully sprinkled 13R.1 hour fire-rated ceiling assembly.Several penetrations are located within the ceiling membrane. Floor …